I Want to Save Operating Point Info At Certain Time Points of a Transient Run In Spectre. How to Fill Out the ADE Transient Options Form?

You won't find it written down anywhere, but, you HAVE to have the box checked for "Save Final Op Pt". How are you supposed to know that? IDK. Why Cadence can't after 30 or 40 years give you a tooltip when you enter value into the infotimes field? IDK.

So, if you're running to 10 us and you want to be able to look at OP info at 1 us (say) and you DON'T care about final OP (at 10 us), you still have to check that box and enter 1 us in the infotimes field. And you're good to go. Sim done, go to Results > Annotate > Transient Operating Point Info and choose the correct time in the resulting dialog.