Resources Saving Hacks You Don't Want to Miss Out On When Running Monte-Carlo
BLUF : Ensure you turn OFF (uncheck the checkbox) saving of final OP point (if your MC involves transient analysis) and ensure the Simulation > Options > Analog > Check does not have "both" or "file" for destination (disk usage)
What's bad (or good) about the default setup?
It saves the final Operating Point (OP) in a transient sim
It writes assert information to the log file (note, you need it in the sqldb for the Device Checks to be useful)
Now, given that the Monte Carlo setup is so nice as to NOT save all (but only explicitly selected) waveforms (even though the setup in ADE says to Save All) unless told to, why can't it do the same with the mostly (in MC) information that's generated from the default setup (see above two bullets)